Case Study

PIHA HOUSE

piha - west auckland
Motivation & Brief

The original brief was to add a new kitchen and bathroom, upgrade the window joinery, add a guest bedroom and overall improve the thermal performance by increasing insulation and air tightness.

This was actually quite a recentely build house. An all concrete house, built in 2008 

345sqm of floor area plus 70sqm of concrete terraces.
2 Storey, 3 Bedroom, 2 Bathroom

  • Site Area: 8391sm
  • Elevated 104m above sea level
  • Very High Wind Zone 
  • Faces West & Northwest
  • Sea Spray Zone

    Zone:  Residential – Rural & Coastal settlement
    Natural Heritage: WaitakereRanges Heritage Area Overlay
    Natural Resources: Significant Ecological Areas Overlay

 

As we got into the project we discovered things during the demolition including quite extensive mould behind all the linings and inside the ceiling spacing and at that point it was decided to undertake a full renovation that of a passive house EnerPHit. This was mainly driven by the owner due to ongoing personal health issues resulting of years of exposure to damp moulding housing conditions.

Start Date : MAY 2019
Completion Date: FEB 2022

Design Specification - Existing vs Renovated

  • Concrete block walls
  • Ground Slab
  • Suspended Mid Floor Slab & Terraces
  • Aluminium Standard windows ( non thermally broken with single glazing
  • Minimal internal Insulation – 25mm EPS polystyrene on the inside and Batts in the ceiling
  • Butynol membrane cold roof
  • Plaster system Cladding

Project Team

Architect   – Sang Architets
Structural Engineers – Richards Consulting Engineers
Certified Passive House Designer – Sustainable Engineering
Main Contractor – Bruyere Passive Homes
Windows – Seda Windows
Cladding – Stotherm Installed by Plaster Solutions
Warm Roof – Nutralite Warm Roof 
MHRV incl Dehumidification – Wolf System from Edge Innovation
DHW Hot Water Heat Pump – Edge Innovation
Solar PV & Solar Hot Water – Solar King
Electrical – Maximum Power
Plumbing – R & L Plumbing
Louvre Roof – Johnson & Cousins
Glass Balustrades & Screens – Viridian Glass/ Euro Glass

Passive House Builders

Demolition & What Was Exposed

Framing Treatment and Levelling Compound Applied to Mid Floor

Air Tightness Issues Tapped

Previous slide
Next slide

Putting it back together

Thermal Bridging and Insulation

Roofing and Solar Installation

The Final Award Winning Result

National Awards Won

National APL Sustainable & Environmental Excellence

Top 100

Regional Awards Won

Regional Supreme Renovation of the Year

Regional Category Winner

Regional Gold